FPM8000 Portable patient monitor --(CE Approved)

FPM8000 Portable patient monitor --(CE Approved)
Product Detailed
FPM8000 Portable patient monitor Patient monitor medical monitor surgical monitor medical equipment

Product detail

15''  color super light LCD display with maximum 9 waveforms;

Display resolution 1024768 pixels;

7-lead waveforms rolling display synchronized;

Monitoring parameters including ECG/RESP, NIBP, SPO2, PULSE RATE and DUAL-TEMP;

Maximum 96-hour graphic and tabular trends of all parameters;

Arrhythmia analysis, multi-lead S-T segment and pacemaker detection;

ECG waveforms cascade;

5-min ECG real time waveform storage and review;

50-set vital sign data recall;

Net working capacity;

Operation Environment

Power Requirements:AC 100-250V ,50/ 60Hz

Temperature:1030

Humidity:≤70%

Application Scope

Adult, child and neonatal

ECG

Lead type:5-lead or 3-lead selectable

Input:5-lead: RA;LA;RL;LL;V or R;L;N;F;C

3-lead: RA;LA;LL or R;L;F

Lead Selection:I;II;III;avL;avF;Vx;CAL

Gain selection: 0.25;0.5;×1;×2;Auto

Sweep speed:12.5 mm/s,25mm/s.50mm/s

Heart Rate range: Adult:15-300bpm

Pediatric/Neonatal:15-350bpm

Accuracy:±1bpm or ±1%, whichever is greater

Resolution:1pm

CMRR:Diagnostic mode: >90dB

Monitoring mode:>105dB

Operating mode:>105dB

Protection:withstand 4000VAC/50Hz voltage in isolation, against electrosurgical

Calibration Signal:1mV±5%

Operation Modes:Diagnostic, Monitor, Surgery

Bandwidth:0.05-100Hz

Alarm Range: Adult: 15-300bpm

Pediatric/Neonatal: 15-350bpm

S-T detection:YES

Measurement range: -2.0mV~2.0mV

Alarm range: -2.0mV~2.0mV

Arrhythmia analysis:YES

Pacemaking Analysis:YES

Respiration

Method:RA-LL impedance

Measurement range: Adult:6-120rpm

Pediatric/Neonatal:6-150rpm

Resolution:1pm

Accuracy:±2% or ±2rpm,whichever is greater

Alarm Range:Adult: 6-120rpm

Pediatric/Neonatal: 6-150rpm

Apnea alarm:YES

Apnea delay: 10-40 seconds

NIBP

Method:Automatic Oscillometric

Operation modes:Manual /Automatic/Continuous

Measurement unit: mmHg /kPa selectable

Measurement types: Systolic, Diastolic, Mean pressure

Measurement range: Adult: 0-250mmHg

Pediatric: 0-200mmHg

Neonatal: 0-180mmHg

Over-pressure protection: YES

Resolution:1mmHg

Accuracy:Mean error and standard deviation per ANSI/AAMI SP-10

Alarm:Systolic, Diastolic, Mean

SpO2

Measurement range: 0-100%

Resolution:1%

Accuracy:+2 digit (70~100%);

0~69%unspecified

Alarm range:1~100%

Pulse rate:Range:20~250bpm

Resolution: 1bpm

Accuracy: ±1bpm

Alarm range: 20~250bpm

Temperature

Measurement range: 0~50.0

Resolution:0.1

Accuracy :±0.1

Alarm range:0~50.0

Channel:1channel/2channel(option)